System Sensor Interface and Input/Output Modules in Bhopal

Fire Protection System (FPS), a System Sensor dealer in Bhopal, supplies System Sensor addressable modules for Series 200 loops: M200E and M200EA input/output modules, a 240VAC mains switching module, conventional zone monitor modules, multi-way modules and the M501MEA mini input module, plus the S300ZDU zonal display for Series 300 conventional systems. FPS installs, programs and maintains them across Madhya Pradesh.

Where to use Interfaces & Modules

  • Monitoring sprinkler waterflow switches, call points and security contacts on an addressable loop
  • Switching sounders, strobes, door closers and other ancillary devices
  • Switching 240VAC loads on command from the fire panel (M201EA-240)
  • Bringing existing conventional detector zones onto an addressable system
  • Zones of intrinsically safe conventional detectors (CZR versions)
  • Panels and enclosures with DIN rail mounting
  • Series 300 conventional systems that need the address of the detector in alarm (S300ZDU)

System Sensor Interfaces & Modules models

How to choose

Modules connect things that are not detectors to an addressable fire alarm loop. An input module watches a contact, such as a waterflow switch, call point or security contact, and reports its state to the panel. An output module switches something on command from the panel, such as sounders, strobes or door closers. A conventional zone module lets a zone of ordinary conventional detectors report through an addressable loop. The addressable modules here belong to the System Sensor Series 200 Advanced range, and most set their address on rotary switches.

For single modules, choose between the M200E and M200EA series. The M200E series offers the M200XE short circuit isolator, M201E single output, M210E single input, M220E dual input and M221E dual input, single output modules on a common platform for box, panel and DIN rail mounting, with tri-colour LEDs and address switches visible in two planes. The M200EA series offers the M201EA, M210EA, M220EA and M221EA, with enlarged light pipes, the panel reading the module supply voltage, and readiness for a 48V high power loop. On the M221E and M221EA the output is rated 2A at 30VDC, resistive load. For 240VAC loads, the M201EA-240 has a latching double pole output (one normally open, one normally closed) and mounts on a 35mm DIN rail.

For conventional zones, the M210E-CZ and M210EA-CZ families connect a zone of conventional detectors to the loop and report open circuit and short circuit faults; the CZR versions also accept intrinsically safe (IS) conventional detectors. Where many points are needed in one place, the CR-6 (six relay), SC-6 (six supervised control), CZ-6 (six conventional zone) and IM-10 (ten input) multi-way modules save fitting many single modules. The M501MEA is a mini input module small enough to fit inside devices or junction boxes, and the S300ZDU shows on a 4 digit LCD the address of the Series 300 detector in alarm.

FPS supplies, installs, programs and maintains System Sensor modules in Bhopal and across Madhya Pradesh.

Frequently asked questions

What is an input/output module in a fire alarm system?
It is an addressable device on the loop that either monitors a contact (input) or switches a load on command from the panel (output). System Sensor modules are used to supervise and activate sounders, strobes, door closers, call points, waterflow switches and other ancillary devices.
Can I connect conventional detectors to a System Sensor addressable system?
Yes, through a conventional zone monitor module such as the M210E-CZ, M210EA-CZ or the six-zone CZ-6. The module reports alarms and open or short circuit faults on the zone wiring to the panel.
What does a built-in short circuit isolator do?
It separates a short circuited section of the loop so the rest of the loop keeps working. The M200E and M200EA series have built-in isolators that can be selected or deselected module by module.
Which System Sensor module switches mains voltage?
The M201EA-240 is a loop-powered module with a latching double pole output suitable for managing 240VAC loads. It mounts directly on a standard 35mm DIN rail.
What does the S300ZDU zonal display unit show?
It is a wall mounted unit on a Series 300 detector circuit that displays the numeric address of the detector in alarm on a 4 digit LCD. If more than one detector is in alarm it scrolls through the addresses, and it also shows short circuit wiring faults.
Does FPS install System Sensor modules in Bhopal?
Yes. FPS is a System Sensor dealer and supplies, installs, programs and maintains System Sensor modules in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.