System Sensor ECO1003A Conventional Photoelectric Smoke Detector (ECO1000)
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.
Fire Protection System (FPS), a System Sensor dealer in Bhopal, supplies System Sensor conventional detectors: ECO1000, Series 300 and Vision smoke, heat and photo-thermal detectors, the PSE/CE and HSE/CE detectors, and intrinsically safe smoke and heat detectors. FPS installs, tests and maintains them on conventional fire alarm zones across Madhya Pradesh.
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.
A multi-criteria conventional detector that combines an optical chamber and a thermal element with a microprocessor, for a faster response to real fires and fewer environmental false alarms.
Three conventional heat detectors covering 58°C and 78°C fixed temperature and rate of rise, for small to medium systems such as small industrial units, retail units and guest houses.
A Series 300 photoelectric smoke detector that works on a conventional zone but adds intelligent maintenance features through a hand-held tool.
A Series 300 photo-thermal detector whose on-board processor only signals an alarm once it is satisfied that a fire has started, reducing nuisance alarms while improving response.
Three Series 300 heat detectors: 58°C fixed temperature (5351TE), 78°C fixed temperature (4351EA) and rate of rise (5351EA), with a latching LED and an optional remote LED annunciator.
A low profile photoelectric smoke detector from the Vision range, for small, straightforward systems, with a response to flaming fires similar to an ionisation detector but no radioactive source.
A Vision multi-criteria detector that combines an optical chamber and a thermal element for a faster response to real fires and fewer environmental false alarms.
Three Vision heat detectors: 58°C fixed temperature (2020F), 78°C fixed temperature (2020HF) and rate of rise (2020R), each with a latching LED.
A Series 300 photoelectric smoke detector with three preset alarm thresholds and advanced maintenance through a remote hand-held test unit. It fits Series 100 detector bases.
A low profile Series 300 photoelectric smoke detector with a bi-colour LED, backward compatible with Series 100 detector bases for upgrading existing installations.
Series 300 rate of rise and fixed temperature heat detectors for places such as bars or kitchens where airborne contamination makes smoke detectors unsuitable.
A low profile conventional photoelectric smoke detector supplied with its base in the pack, with a magnet for field testing.
A low profile conventional heat detector tested to EN 54-5 Class A2R, supplied with its base in the pack.
An intrinsically safe conventional photoelectric smoke detector for open area protection, used with 2-wire control panels through an interface module.
An intrinsically safe conventional 2-wire heat detector with a thermistor sensing circuit, for open area protection with 2-wire panels through an interface module.
In a conventional system detectors are wired in zones, and the panel shows which zone is in alarm rather than which detector. First pick the sensing type. Photoelectric smoke detectors use an optical chamber that works on the light scattering principle and suit most rooms. Heat detectors suit kitchens, bars and other places where smoke or airborne contamination would cause false alarms; they come as 58°C or 78°C fixed temperature types or rate of rise types. Photo-thermal (multi-criteria) detectors combine smoke and heat sensing for a faster response to real fires and fewer unwanted alarms. EN 54-7 is the European standard for smoke detectors and EN 54-5 for heat detectors.
Then pick the range. ECO1000 detectors run on 8 to 30VDC (12 or 24VDC systems), are rated -30 to +70°C, carry EN 54 and MED 96/98/EC approvals, and have a latching LED, a remote alarm test option and bases with or without a relay. Series 300 detectors act conventionally but add intelligent features: with a hand-held tool you can set sensitivity, read the last maintenance date and chamber contamination, and test the alarm, and the S300ZDU display can show which detector is in alarm. Vision detectors run on 14 to 28VDC and are aimed at small, straightforward systems, with standard and deep bases with or without a Schottky diode.
The 2351/EIA, 2351/EC, 5351/E and 4351/E are Series 300 detectors that fit Series 100 detector bases, which helps when upgrading or extending an existing installation. The PSE/CE smoke detector and HSE/CE heat detector come with the base in the pack and can be tested in the field with a magnet. For hazardous areas, the JTY-GD-2151EIS smoke detector and JTWB-BCD-5151EIS heat detector are intrinsically safe conventional detectors connected to 2-wire panels through an interface module; ask FPS for the intrinsic safety certification details for your site.
FPS supplies, installs and maintains System Sensor conventional detectors in Bhopal and across Madhya Pradesh.