Bosch FAP-425-O and FAP-425-O-R Optical Smoke Detectors, AVENAR detector 4000
Analog addressable smoke detectors with one optical sensor. The FAP-425-O sets its address automatically; the FAP-425-O-R adds rotary switches for manual addressing.
Fire Protection System (FPS), a Bosch dealer in Bhopal, supplies Bosch analog addressable fire detectors for LSN systems: the AVENAR detector 4000 range of optical, dual-optical, heat, multisensor and CO detectors, and the ultra-flat FAP-520 detectors. FPS installs, commissions and maintains them across Madhya Pradesh.
Analog addressable smoke detectors with one optical sensor. The FAP-425-O sets its address automatically; the FAP-425-O-R adds rotary switches for manual addressing.
Analog addressable multisensor detectors with one optical and one heat sensor. The FAP-425-OT is auto-addressing; the FAP-425-OT-R also has rotary switches.
An analog addressable smoke detector with two optical sensors (Dual-Ray technology) for early detection of light smoke, with manual and automatic addressing.
An analog addressable multisensor detector with two optical sensors and one heat sensor, with manual and automatic addressing.
An analog addressable multisensor detector with two optical sensors, one heat sensor and one CO gas sensor, with manual and automatic addressing.
An analog addressable detector with two optical sensors, one heat sensor and one CO gas sensor, whose CO cell Bosch rates for a 10 year life.
An analog addressable heat detector with one thermal sensor, for fires with a rapid temperature rise or a maximum temperature, with manual and automatic addressing.
An analog addressable optical smoke detector in an ultra-flat design for flush ceiling installation on LSN improved systems.
An analog addressable multisensor detector with an optical sensor and an additional gas sensor, in an ultra-flat design for flush ceiling installation on LSN improved systems.
An analog addressable detector has its own address on the loop, so the fire panel shows exactly which detector is in alarm. These Bosch detectors connect to LSN (Local SecurityNetwork), Bosch's addressable loop bus. In the AVENAR detector 4000 range, a model code ending in -R has rotary switches for manual addressing as well as automatic address setting; the versions without -R set their address automatically.
Choose the sensing principle for the risk. O is a single optical (smoke) sensor, OT adds a heat sensor, DO has two optical sensors (Dual-Ray) that Bosch says detect the lightest smoke, and DOT combines dual-optical and heat. The DOTC-R and DOTCO-R add a CO (carbon monoxide) gas sensor, which Bosch describes as reacting quickly to smouldering fires and suiting areas with dust, steam or cooking vapour. The DOTCO-R has a CO cell with a 10 year life and Bosch states its response sensitivity follows EN 54-26, EN 54-30 and EN 54-31. The FAH-425-T-R is a heat detector for fires with a rapid temperature rise or a maximum temperature.
The FAP-520 detectors are an ultra-flat design for flush ceiling installation on LSN improved systems, available as an optical smoke detector (FAP-O 520) or an optical/chemical multisensor (FAP-OC 520). They need the FAA-500 base; AVENAR detector 4000 detectors use bases such as the MS 400. Every model has its own approvals listed below, so check them against your project specification.
FPS supplies, installs, commissions and maintains Bosch addressable detectors in Bhopal and across Madhya Pradesh. Confirm the exact part number and base with FPS before ordering.