Wet Pipe Sprinkler System in Bhopal

A wet pipe system is the sprinkler system most buildings have: pipes always full of water under pressure, closed sprinkler heads that open one by one over a fire, and an alarm valve at the riser that raises the alarm the moment water flows. FPS designs, supplies, installs and maintains wet pipe systems in Bhopal and across Madhya Pradesh, with valves and heads from Tyco, HD Fire, Kartar Valves, New Age and System Sensor.

Also called
automatic sprinkler system, wet sprinkler system, wet system, alarm valve sprinkler system, installation control valve (ICV) system
Used for
Offices, hotels, hospitals, schools, malls, basements, car parks, factories and warehouses that stay above freezing
Brands
Tyco, HD Fire, Kartar Valves, New Age, System Sensor
Supplied by
Fire Protection System, Bhopal (supplier for Tyco and New Age; dealer for HD Fire and System Sensor; authorised distributor for Kartar Valves), across Madhya Pradesh
Price
On request: WhatsApp or call +91 92440 89060

Which one do you need?

Heads under a false ceilingPendent sprinklers, Concealed sprinklers
Heads on exposed pipes (sheds, plant rooms, warehouses)Upright sprinklers
Heads on a wall (hotel rooms, corridors)Sidewall sprinklers
The valve set at the riserAlarm valves, Gongs and gauges
Floor and zone monitoringZone control and flow switches
Cold store or freezerDry pipe valves

How a wet pipe sprinkler system works

Water fills the whole pipe network all the time, held under pressure by a jockey pump, the fire pumps or an overhead tank. Each sprinkler head is closed by a glass bulb or a solder link. When the hot gases from a fire heat a head to its rating, usually 68°C, the bulb breaks and that head alone starts to spray. Most fires are controlled by the first few heads.

At the riser sits the installation control valve: a main stop valve, the alarm valve, pressure gauges, a test and drain valve and the line to a water motor gong. When a head opens, the alarm valve's clapper lifts, water runs to the gong outside the building and to a pressure switch, and the fire alarm panel is told. Flow switches on each floor or zone show where the water is going.

Wet pipe systems are the simplest kind and the quickest to respond, because water is already at every head. They suit any space that stays above freezing. In cold stores, a dry pipe system keeps the pipes filled with air instead.

  • Offices and IT parks
  • Hotels and hospitals
  • Schools and colleges
  • Malls, shops and showrooms
  • Basements and car parks
  • Factories and warehouses

Alarm valves (installation control valves)

The alarm valve, also called the alarm check valve, holds water in the system, stops it flowing back and starts the alarm when a sprinkler opens. HD Fire's Model H comes in 80 to 200 NB in ductile iron, UL Listed, FM Approved and CE marked. New Age offers a UL Listed alarm check valve in 4 and 6 inch, and Tyco's AV-1-300 is rated 300 psi in DN65 to DN200.

ModelKey facts
Tyco Model AV-1-300 Alarm Check Valve, 300 psi (TFP910)Alarm check valve, Wet pipe systems, 300 psi, DN65, DN100, DN150, DN200
Tyco Model AV-1-300 Alarm Valve, European Conformity Trim (TFP990)Alarm valve, European Conformity trim, DN65, DN100, DN150, DN200, FM, VdS, LPCB
HD Fire Alarm Valve Model H, Ductile Iron, 80 to 200 NBAlarm valve, 80 to 200 NB, Ductile iron, UL, FM, CE
New Age Alarm Check Valve, UL Listed, 4 and 6 inchUL Listed, Alarm check valve, 4 inch / 6 inch, ANSI B16.5 flanged

Water motor gongs, retard chambers and gauges

A water motor gong rings outside the building whenever water flows through the alarm line, with no power needed. Where the supply pressure varies, a retard chamber stops surges from setting off false alarms, and pressure relief trim lets off the pressure that builds up when the pipes warm. Gauges show the pressure on both sides of the valve.

ModelKey facts
Tyco Model RC-1 Retard Chamber, 300 psi (TFP920)Retard chamber, Variable pressure supplies, 300 psi, For AV-1-300
Tyco Model WMA-1 Water Motor Alarm (TFP921)Water motor alarm, Hydraulic gong, Outdoor wall mounting, UL, ULC, FM
Tyco Model WMA-1 Water Motor Alarm, European Conformity, 16 bar (TFP922)Water motor alarm, European Conformity, 16 bar, FM, VdS, UL, LPCB, CE
HD Fire Water Motor Gong Bell for Deluge ValvesWater motor gong, Aluminium alloy, UL Listed and FM Approved, Outdoor alarm
HD Fire Retard Chamber, Stainless Steel, 1 GallonRetard chamber, Stainless steel, 3.8 litre, UL Listed and FM Approved
HD Fire Water Motor Gong Bell for Alarm ValvesWater motor gong, Aluminium alloy, UL Listed and FM Approved, Outdoor alarm
HD Fire Pressure Gauges HDP-1 and HDP-2, 0 to 300 psi, UL Listed and FM ApprovedPressure gauge, 0 to 300 psi, Stainless steel case, UL Listed and FM Approved
HD Fire Water Motor Gong Bell, Aluminium AlloyWater motor gong, Aluminium alloy, UL Listed and FM Approved, Outdoor alarm
Tyco Pressure Relief Trim for Alarm Check Valves, 175 and 185 psi (TFP930)Pressure relief trim, Wet pipe systems, 175 or 185 psi, Galvanized fittings

Floor and zone control

Large buildings are split into zones, each with its own control point, so the fire alarm shows the floor or area where water is flowing and one zone can be shut for work without draining the rest. The HD Fire zone control manifold brings a flow switch, test drain, pressure gauge and relief valve together in 2.5 to 8 inch, and Tyco RM-2 riser manifolds do the same on 2 to 6 inch risers. System Sensor waterflow detectors fit steel pipe from 2 to 8 inch, and its supervisory switches tell the panel if a control valve is closed.

ModelKey facts
Tyco Model CV-1FR Grooved-End Riser Check Valve, DN50 to DN300 (TFP950)Riser check valve, Grooved ends, DN50 to DN300, 300 psi
Tyco Model RM-2 Riser Manifold, 2 to 6 Inch (TFP964)Riser manifold, DN50 to DN150, 300 psi, Floor control
Tyco Model TD-2 Test and Drain Valve, K2.8 and K4.2 Test Orifice (TFP965)Test and drain valve, K2.8 and K4.2 orifice, Integral pressure relief, UL, ULC, FM
Tyco Model RM-2 Base Riser Manifold, Commercial and Residential, DN32 to DN80 (TFP966)Riser manifold, Commercial and residential, DN32 to DN80, 300 psi
HD Fire Test and Drain Valve, Brass, UL Listed and FM ApprovedTest and drain valve, K 5.6 or 4.2, 300 psi, UL Listed and FM Approved
HD Fire Zone Control Manifold Assembly, 2.5 to 8 inchZone control manifold, 2.5 to 8 inch, 175 psi, Sprinkler zones
Kartar Valves Test and Drain Valve, SS 304, PN-20 (K922 TDV)Test and drain valve, SS 304, PN-20, 25 mm to 50 mm
System Sensor PIB-V2 Supervisory Switch for Post Indicator and Butterfly ValvesPIB-V2, Supervisory switch, Post indicator valve, Butterfly valve
System Sensor OSY2 Supervisory Switch for OS&Y Gate ValvesOSY2, Supervisory switch, OS&Y gate valve, Indoor and outdoor
System Sensor WFD Series Waterflow Detector, 2 to 8 inch Steel PipeWFD series, Waterflow detector, 2 to 8 inch pipe, NEMA 4
System Sensor WFDT Vane-type Waterflow Detector for 1 inch TeesWFDT, Vane-type, 1 inch NPT branch, Waterflow detector
Tyco Model FSA(C) Compact Flow Switch Assembly, Riser Manifold with Test and Drain, AS 2118 (TFP967)Flow switch assembly, Floor identification, AS 2118 Parts 1 and 6, Galvanised or painted

Sprinkler heads for a wet pipe system

A wet pipe system can use every type of head. Choose the type by where it is mounted, then the K factor, response and temperature the design calls for. Each page compares every model of one type:

Pendent sprinklers › Upright sprinklers › Concealed sprinklers › Sidewall sprinklers › All fire sprinklers ›

Dry pipe valves for cold stores

Where pipes could freeze, such as cold stores and unheated loading bays, the pipes hold air or nitrogen under pressure instead of water. When a head opens, the air escapes, the dry pipe valve opens and water flows to the open head. We supply Tyco DPV-1 dry pipe valves in DN65 to DN150, with mechanical or electronic accelerators that open the valve sooner and air or nitrogen maintenance devices that hold the pressure. Dry-type heads stop water standing in the drop to the head.

ModelKey facts
Tyco Model DPV-1 Dry Pipe Valve, External Resetting, DN65 to DN150 (TFP1020)Dry pipe valve, DN65 to DN150, 250 psi, Ductile iron
Tyco Model DPV-1 Dry Pipe Valve and ACC-1 Accelerator, European Conformity Trim, 16 bar (TFP1090)Dry pipe valve, European Conformity, 16 bar, DN65 to DN150
Tyco VIZOR Electronic Dry Pipe Accelerator (EDPA) (TFP1105)Electronic accelerator, Dry pipe systems, Battery back-up, UL, ULC
Tyco Model ACC-1 Dry Pipe Valve Accelerator, External Resetting (TFP1112)Mechanical accelerator, For DPV-1, 250 psi, UL, ULC, FM, LPCB
Tyco Model QRS-2 Electronic Accelerator for Dry Pipe or Preaction Systems (TFP1120)Electronic accelerator, Dry pipe or preaction, DN65 to DN150, Battery back-up
Tyco Model AMD-1 Air Maintenance Device, Pressure Reducing Type (TFP1221)Air maintenance device, Pressure reducing, 5 to 70 psi, UL, C-UL, FM
Tyco Model AMD-2 Air Maintenance Device, Compressor Control Type (TFP1231)Air maintenance device, Compressor control, Field adjustable, UL, C-UL, FM
Tyco Model AMD-3 Nitrogen Maintenance Device, High Pressure Cylinder Type (TFP1241)Nitrogen maintenance device, Cylinder supply, 4 to 60 psi, UL, C-UL, FM

Dry sprinklers ›

How to choose

Start with the hazard. Sprinkler standards sort buildings into hazard classes, from light hazard for offices, hotels and hospitals to ordinary hazard for shops, car parks and most factories, and higher classes for stores of flammable goods. The class sets the water density, the area each head covers and how long the water supply must last.

Then the heads: pendent heads under a false ceiling, concealed heads where the ceiling must look clean, upright heads on exposed pipes and sidewall heads where the pipe runs along a wall. Quick response heads with a 3 mm bulb are usual in offices, hotels and hospitals, and standard response heads with a 5 mm bulb in factories and stores.

Finally the water: a hydraulic calculation sizes the pipes and confirms that the pumps and tank give the design flow at the farthest heads. We do the survey, the design and drawings for the fire NOC, the installation, the pressure, flow and alarm tests, and the AMC.

Frequently asked questions

What is a wet pipe sprinkler system?
A sprinkler system whose pipes are always full of water under pressure. Each closed head opens on its own when the heat of a fire reaches its rating, so water reaches the fire at once, and the alarm valve at the riser sounds the alarm.
What is an installation control valve (ICV)?
The valve set at the base of a sprinkler riser: the main stop valve, the alarm valve, pressure gauges, a test and drain valve and the line to the water motor gong. It controls and monitors the water to one installation. See the alarm valves on this page.
What is the difference between a wet pipe and a deluge system?
A wet pipe system has closed heads that open one at a time over the fire. A deluge system has open heads or nozzles on dry pipes: when the detection system operates, the deluge valve opens and water flows from all of them at once, for transformers, conveyors and other high hazards.
Which sprinkler temperature rating should I use?
68°C, a red bulb, is the standard rating for most rooms. Spaces that run hot, such as boiler rooms, areas near cooking equipment or under roof glazing, need a higher rating such as 79°C (yellow) or 93°C (green). See the bulb colour chart.
Do you maintain sprinkler systems?
Yes. Our AMC covers the valve sets, gongs, flow switches, gauges and pumps, a flow test at the test and drain valve, a check of the heads for paint, damage or blockage, and the spare sprinkler cabinet.
How much does a sprinkler system cost?
It depends on the floor area, the hazard, the number of heads and zones, the pipe, and the pumps and tank, so we quote after a free site survey. Send the drawings or the floor area and use on WhatsApp at +91 92440 89060. Our sprinkler cost guide explains what drives the price.