Ceasefire Fire Alarm and Detection Systems in Bhopal

Fire Protection System is an authorised Ceasefire distributor in Bhopal, supplying conventional and Intelli-Sense addressable fire alarm panels, detectors, manual call points, sounders, loop modules, network and monitoring equipment, and Wave-Sense wireless devices. Most of the range is designed and tested to the EN 54 series of fire alarm standards, with LPCB, BSI or IMQ certification on many devices.

Where to use Fire Alarm & Detection

  • Offices, IT parks and commercial buildings
  • Factories, plants and warehouses
  • Hospitals, hotels and hostels
  • Schools, colleges and large institutions
  • Malls, cinemas and multiplexes
  • Multi building campuses on one networked system
  • Buildings where new cabling is hard (wireless devices)
  • Gas suppression areas (extinguishing control panel)
  • Ventilation ducts (duct detector housing)
  • Homes and small offices (stand alone smoke alarms, gas leak detector)

Ceasefire Fire Alarm & Detection models

Ceasefire Isolator Module (TI-002225)

IsolatorAddressable loopEN 54-17

Loop powered module that opens the loop automatically when it detects a short circuit, so the fault does not take down the whole loop, and resets itself once the short is cleared. It can cut off up to 32 Intelli-Sense Lite devices and is designed to EN 54-17.

View specifications ›

Ceasefire Duct Detector Housing (TI-002229)

Duct detector housing0.5 to 2.0 m/s airflowEN 54-27

Air sampling housing that lets a smoke detector check the air inside a ventilation duct, for air speeds of 0.5 m/s to 2.0 m/s. It takes Intelli-Sense, Pro-Sense and Wave-Sense smoke detectors and is designed to comply with EN 54-27.

View specifications ›

How to choose

First choose the system type. A conventional panel divides the building into zones and shows which zone is in alarm; Ceasefire's conventional panels run from 2 to 32 zones and are approved to EN 54-2 and 4. An addressable panel gives every detector and device its own address, so the panel shows the exact device in alarm. The Intelli-Sense addressable panels take up to 240 devices per loop, from 1 loop up to 8 loops, and network up to 2000 zones. A loop is the cable circuit that runs from the panel through all the devices and back.

Then pick the field devices. Multi-criteria detectors combine smoke and heat sensing, heat detectors respond to temperature instead of smoke, manual call points let people raise the alarm by hand, and sounders, beacons and base sounders give the warning. Detectors with a built-in isolator, or separate isolator modules, keep the rest of the loop working if the cable is shorted, and input, output and relay modules let the panel monitor contacts or switch other equipment.

Where cabling is difficult, Wave-Sense wireless devices join an addressable loop through a translator module, with expanders for more reach; each expander handles 32 wireless devices, and field devices reach up to 150 m in open space. For larger sites, network cards, remote terminals, graphic software, IP gateways and a BMS interface let you view and control the system from other buildings or a PC. FPS supplies, installs and maintains Ceasefire fire alarm systems in Bhopal and across Madhya Pradesh.

Frequently asked questions

What is the difference between conventional and addressable fire alarm systems?
A conventional system reports alarms by zone, so you know the area but not the exact device. An addressable system gives each detector, call point and module its own address, so the panel shows exactly which device operated; Ceasefire's Intelli-Sense panels support up to 240 devices per loop.
What does EN 54 mean on these products?
EN 54 is the European standard series for fire detection and alarm equipment, and each part covers one type of device, for example EN 54-2 for control panels, EN 54-5 for heat detectors, EN 54-7 for smoke detectors and EN 54-11 for manual call points. Many Ceasefire devices are also certified by LPCB, BSI or IMQ.
When should wireless fire alarm devices be used?
Wave-Sense wireless devices suit buildings where running cable is hard or disruptive. They join an addressable panel through a translator module, communicate both ways on 865 MHz and reach up to 150 m in open space.
What is an isolator and why is it needed?
An isolator opens the loop on either side of a short circuit so the other devices keep working, and resets itself once the fault is cleared. Ceasefire offers detectors and modules with built-in isolators as well as a separate isolator module.
Can the fire alarm be monitored remotely or linked to a BMS?
Yes. IP gateway cards give access to an Intelli-Sense network through a standard web browser with email alerts, the Commander module links it to a BMS over BACnet or Modbus, and the graphic control software shows the system on a PC.
Does FPS install and maintain Ceasefire fire alarm systems?
Yes. FPS supplies, installs and maintains Ceasefire fire alarm systems in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.